SICK E100 Series Safety Enabling Switch, 2 NO/2 NC, IP65

ไม่พร้อมจำหน่ายในตอนนี้
ขออภัย เราไม่ทราบว่าสินค้านี้จะกลับมาในสต็อกเมื่อใด
RS Stock No.:
285-9486
หมายเลขชิ้นส่วนของผู้ผลิต / Mfr. Part No.:
E100-B2A22S10A
ผู้ผลิต:
SICK
ค้นหาผลิตภัณฑ์ที่คล้ายกันโดยเลือกคุณลักษณะอย่างน้อยหนึ่งรายการ
เลือกทั้งหมด

Brand

SICK

Series

E100

Product Type

Safety Enabling Switch

Contact Configuration

2 NO/2 NC

IP Rating

IP65

Terminal Type

Cable

Housing Material

Plastic

Minimum Operating Temperature

-5°C

Maximum Operating Temperature

50°C

Contact Voltage

24V dc

Standards/Approvals

China RoHS, cULus, EC-Type Examination, EN, EU DoC, TPC, UKCA

Hazardous Area Certification

No

Mechanical Life

100000Cycles

Width

64mm

Length

132mm

COO (Country of Origin):
DE

SICK E100 Series Safety Enabling Switch, 24V DC Contact Voltage, IP65 - E100-B2A22S10A


This safety enabling switch is a command device designed to control access and machine functions in industrial settings. It provides a combination of normally open and normally closed contacts for safety interlocking and operator inputs, housed in a plastic enclosure suitable for dusty or damp environments. The unit operates across typical factory temperatures and connects via a 10m PUR cable with multiple conductors for straightforward wiring to safety logic.

Features and Benefits:


• 2NO2NC contact configuration for versatile safety wiring
• 24V DC rated contact voltage for common safety control systems
• IP65 enclosure rating for protection against dust and water jets
• Mechanical life 100,000 cycles to support frequent operation
• Cable Terminal connection with 10m PUR cable for flexible installation

Applications


• Suitable for guarding and interlock functions on production lines
• Ideal for integration with safety logic units in machinery control
• Used with access control points requiring cable-connected switches
• Can be used for operator command stations in manufacturing plants

What fault behaviour should be expected from the device?


The switch contains no internal fault detection and cannot assume a safe state by itself

connected safety logic must perform fault monitoring.

What are the electrical endurance and switching capabilities?


It offers a B10d Value of 5x10^5 switching cycles with small loads and supports DC-13 use with rated currents up to 2A at 24V DC.

How is the device connected and what are the cable specifics?


Connection is via a straight cable with open end, 10m length, PUR sheath, 9.8mm diameter and conductors sized 8x0.5mm² and 8x0.14mm².

What approvals and certificates accompany the product?


It carries EU and UK declarations of conformity, China RoHS, cULus certificate, EC-type examination approval and third-party certification.

What environmental limits apply to storage and operation?


The unit is specified for operation and storage between -5°C and +50°C.