SICK E100 Series Safety Enabling Switch, 2 NO/2 NC, IP67

ไม่พร้อมจำหน่ายในตอนนี้
ขออภัย เราไม่ทราบว่าสินค้านี้จะกลับมาในสต็อกเมื่อใด
RS Stock No.:
285-9483
หมายเลขชิ้นส่วนของผู้ผลิต / Mfr. Part No.:
E100-A2A22C05A
ผู้ผลิต:
SICK
ค้นหาผลิตภัณฑ์ที่คล้ายกันโดยเลือกคุณลักษณะอย่างน้อยหนึ่งรายการ
เลือกทั้งหมด

Brand

SICK

Product Type

Safety Enabling Switch

Series

E100

Contact Configuration

2 NO/2 NC

IP Rating

IP67

Terminal Type

Cable

Housing Material

Plastic

Minimum Operating Temperature

-5°C

Switch Contact Current

2A

Maximum Operating Temperature

50°C

Contact Voltage

24V dc

Standards/Approvals

China RoHS, cULus, EC-Type Examination, EN, EU DoC, TPC, UKCA

Hazardous Area Certification

No

Length

132mm

Width

64mm

Mechanical Life

100000Cycles

COO (Country of Origin):
DE

SICK E100 Series Safety Enabling Switch, 24V DC Contact Voltage, IP67 - E100-A2A22C05A


This safety enabling switch provides monitored manual machine access control for industrial environments. It is designed as a cable-connected safety command device with both normally closed and normally open contact configurations for integration into safety logic. The unit is housed in a robust plastic enclosure and operates across typical indoor industrial temperatures.

Features and Benefits:


• 2A switching current supports standard control circuits
• 2 NO 2 NC contacts provide safety and signalling separation
• 100000 cycles mechanical life reduces replacement frequency
• IP67 waterproof rating allows use in wet environments
• Cable Terminal with 5m PUR cable simplifies hardwiring

Applications


• Suitable for guarding on automated production lines
• Ideal for integration with safety controllers for access doors
• Used for machine stop command in packaging systems
• Can be used for conveyor emergency disable functions
• Used with safety logic units for monitored stop scenarios

How is fault handling managed with this device?


The switch has no internal fault detection and depends on the connected safety-related logic unit for fault monitoring.

What are the electrical endurance and contact performance?


The device uses slow-action switching elements with positive-action NC contacts rated for 2A at 24V DC and specified switching current down to 1mA at 24V DC.

What connection and cable specifics should installers note?


It features an open-ended cable with 5m length, 8mm diameter, PUR sheath and 8x0.34mm² conductors

bending radii exceed 7.5x fixed and 15x moving cable diameter.

What standards and approvals accompany the device?


It holds cULus and UKCA approvals Plus EC-Type Examination and EU/UK declarations of conformity alongside China RoHS compliance.