Fluke Networks Pro3000 Tone Generator, 5 Tone, 1000 Hz Tone Frequency

ไม่พร้อมจำหน่ายในตอนนี้
ขออภัย เราไม่ทราบว่าสินค้านี้จะกลับมาในสต็อกเมื่อใด
RS Stock No.:
503-568
Distrelec หมายเลขบทความ:
110-42-705
หมายเลขชิ้นส่วนของผู้ผลิต / Mfr. Part No.:
Pro3000
ผู้ผลิต:
Fluke Networks
ค้นหาผลิตภัณฑ์ที่คล้ายกันโดยเลือกคุณลักษณะอย่างน้อยหนึ่งรายการ
เลือกทั้งหมด

Brand

Fluke Networks

Product Type

Tone Generator

Model Number

Pro3000

Tone Frequency

1000Hz

Number of Tones

5

Power Source

Battery

Battery Type

Alkaline

Standards/Approvals

No

สถานะRoHS: ได้รับการยกเว้น

COO (Country of Origin):
MY

Fluke Tone Generator, 1000Hz Tone Frequency, Alkaline Battery Type - Pro3000


This tone generator is a battery-powered signal source designed to trace and identify communication and cabling pairs in industrial and field environments. It emits selectable cadenced tones to aid pair identification and polarity checks, and is supplied alongside an unfiltered probe with audio monitoring capability for clear cable tracing over long distances.

Features & Benefits


• 1000 Hz nominal solid tone for consistent signal identification
• Alternating 1000/1500 Hz cadence for pair differentiation
• Output 8 dBm into 600 Ω for Detectable signal on long runs
• Continuity mode provides 8V dc output for line verification
• Over-voltage protection at 60V dc for safe connection checks
• 9V alkaline battery operation for field-ready portability

**Applications**


• Suitable for locating faults on twisted-pair network cables
• Ideal for tracing telephone and communication wiring over distance
• Used with probes to confirm pair continuity and polarity
• Can be used for cable routing verification in installations

How many distinct tones are available for pair identification?


Five distinct cadence options are provided so users can change tone patterns by shorting the targeted pair at either end to uniquely mark each pair.

What connection options does the probe provide for audio monitoring?


The probe includes a 3.5mm headphone jack and a volume control allowing direct listening and level adjustment during tracing.

What environmental range supports field operation?


The tools operate between −20 °C and 60 °C and can be stored between −40 °C and 70 °C to suit varied site conditions.

What protection exists when connecting to live lines?


The tone output and polarity functions are safeguarded against voltages up to 60V dc to reduce risk during testing.