Beha-Amprobe AMP 320 Clamp Meter, 600 A 600 A 600 V dc 600 V ac CAT III Non-Contact Voltage Detector

ไม่พร้อมจำหน่ายในตอนนี้
ขออภัย เราไม่ทราบว่าสินค้านี้จะกลับมาในสต็อกเมื่อใด
RS Stock No.:
873-9734
Distrelec หมายเลขบทความ:
300-17-274
หมายเลขชิ้นส่วนของผู้ผลิต / Mfr. Part No.:
AMP-320-EUR
ผู้ผลิต:
Beha-Amprobe
ค้นหาผลิตภัณฑ์ที่คล้ายกันโดยเลือกคุณลักษณะอย่างน้อยหนึ่งรายการ
เลือกทั้งหมด

Brand

Beha-Amprobe

Product Type

Clamp Meter

Maximum DC Current Measurement

600A

Maximum AC Voltage Measurement

600V ac

Maximum DC Voltage Measurement

600V dc

Maximum Resistance Measurement

60kΩ

Model Number

AMP 320

Clamp Meter Type

AC/DC Clamp Meter

AC Current Accuracy

±1.8 % rdg + 5 Digits

AC Voltage Accuracy

±1 % rdg + 5 Digits

DC Voltage Accuracy

±1 % rdg + 5 Digits

Temperature Measurement Accuracy

±1 %

DC Current Accuracy

±2 % rdg + 5 Digits

Resistance Measurement Accuracy

±1 % rdg + 5 Digits

Minimum Operating Temperature

0°C

Maximum Jaw Opening

35mm

Maximum Operating Temperature

40°C

Standards/Approvals

CE

Width

77mm

Height

37mm

Length

224mm

Weight

254g

Functions Measured

Resistance, AC Current, DC Voltage, AC Voltage, Temperature, DC Current

True RMS

Yes

Safety Category Level

CAT III

Battery Type

AAA

Display Type

LCD

Non-Contact Voltage Detector

Yes

Maximum Temperature Measurement

400°C

Maximum AC Current Measurement

600A

Power Source

Battery

Safety Category Voltage

600V

Maximum Conductor Size

35mm

สถานะRoHS: ได้รับการยกเว้น

COO (Country of Origin):
TW

Fluke Clamp Meter, 600A Maximum AC Current Measurement, 600V Maximum DC Voltage Measurement - AMP-320-EUR


This clamp meter is a handheld instrument designed for measuring electrical parameters in industrial and commercial environments. It supports both AC and DC measurements, offers true-RMS readings for accurate waveform assessment, and incorporates a non‑contact voltage detector to identify live conductors safely. The unit is powered by AAA batteries and features an LCD for readouts.

Features and Benefits:


• Measures up to 600A for high-current troubleshooting
• True‑RMS capability ensures accurate AC measurements
• Temperature sensing to 400 °C for thermal diagnostics
• Voltage ranges to 600V for building and equipment checks
• Resistance span to 60 kΩ for circuit continuity verification
• Jaw aperture 35mm accommodates larger conductors

Applications


• Suitable for diagnosing motors and generators in plant
• Ideal for HVAC system temperature and current checks
• Used for testing distribution boards up to 600V
• Can be used for fault-finding in automotive electrical systems
• Used with industrial panels where non‑contact voltage detection aids safety

What accuracy can I expect when measuring AC voltage?


AC voltage readings have an accuracy of ±1% of reading plus 5 digits, providing precise measurement for system verification.

How does it perform on DC current measurements?


DC current measurement accuracy is ±2% of reading plus 5 digits and it measures up to 600A, suitable for monitoring battery and DC supply systems.

What safety rating is applicable for field use?


The instrument meets CAT III safety levels at 600V, appropriate for distribution‑level electrical work.

Which battery type does it use and how does that affect portability?


It runs on standard AAA batteries, keeping the device lightweight at 254 g and convenient for mobile technicians.