Circuit Trips | Auto Reclosers | RS
การค้าหาล่าสุด / Recently searched

    Circuit Trips

    Circuit trips react to ground faults, short circuits or thermal overload in circuit breakers. A circuit trip opens the circuit in the event of a faulty condition. The trip becomes activated when it senses heat from an overload or high current from a short circuit.

    What are the different types of circuit trips?

    There are two types of circuit trips: electromechanical and electronic. An electromechanical circuit trip has two moving parts that work together to determine when to open the circuit. The two parts are a current-sensitive device and a thermal-sensitive device. An electric circuit trip is less mechanical as it's a programmable device. It measures and times the current flowing through the circuit breaker, electronically delivering a trip signal when it's needed.

    How to choose the right circuit trips

    Choosing the right circuit trips depends on the circuit or device and appliance you're using it for. There are various features that should be considered when selecting the right circuit trips, such as rated-control voltage and the current rating.

    An auto recloser is a type of circuit breaker equipped with a mechanism that automatically closes the breaker after it has been opened due to a fault. Reclosers are used to detect overcurrent and interrupt momentary faults in electrical distribution networks. To prevent damage, each station along a network is protected with circuit breakers which turn the power off if there is a short circuit. Reclosers are programmed to automate the reset process and start the restoration service.

    Why Have an Auto Recloser?

    Firstly, reclosers prevent transient short circuits from triggering prolonged power outages. This could be a broken tree branch momentarily hitting an overhead cable before it hits the ground. Having a recloser results in a better service to the customer as the power is restored within a few seconds.

    Secondly, the recloser is able to restore power automatically without the requirement of an engineer unless the fault is more serious.

    362 สินค้าที่แสดงสำหรับ Circuit Trips

    Phoenix Contact
    -
    WF 1000
    WF
    6 mm Cable
    Strip Tool
    120V (Volts)
    -
    -
    ABB
    -
    SACE
    UVR
    XT2, XT3, XT4 Circuit Breakers
    Undervoltage Release
    220 → 240V ac
    -
    -
    Schneider Electric
    100A
    ComPacT
    ComPacT NSX
    NSX160/100/250
    Circuit Trip
    440V (Volts)
    -
    -
    Schneider Electric
    -
    Acti 9
    iMNx
    ARA, ic60 MCB, IDPN Vigi, ild Double Terminal, ilD MCB, iSW-NA, RCA
    Undervoltage Release
    220 → 240V ac
    Yes
    Green Premium
    Schneider Electric
    -
    Acti 9
    iC60
    Circuit Breaker
    Auto Recloser
    -
    Yes
    Green Premium
    Siemens
    -
    Sirius
    3RV2
    3RV2 Series Circuit Breakers
    Shunt Trip
    210 → 240V ac
    -
    -
    Schneider Electric
    40A
    Compact
    Micrologic 4.2
    Compact NSX 100/160/250 Circuit Breakers
    -
    440V ac
    -
    -
    ABB
    -
    -
    S2C
    S200U, S200UP
    Shunt Trip
    -
    -
    -
    ABB
    -
    S800
    S800-UVR
    S800PV, S800S, S800N, S800C, S800B, S800HV, S800U Series
    Undervoltage Release
    220 → 250V ac/dc
    -
    -
    Schneider Electric
    250A
    ComPacT NSX100...250
    LV4
    ComPact (ComPact NSX400) Circuit Breaker
    Earth Leakage Add-on Protection Module
    220 - 440V ac
    -
    -
    Siemens
    -
    SENTRON
    3VA9988
    3VA1, 3VA20-26
    Auxiliary Release
    -
    -
    -
    Schneider Electric
    100A
    Compact
    Micrologic 2.2 G
    Compact NSX 100/160/250 Circuit Breakers
    -
    690V ac
    -
    -
    Eaton
    -
    -
    Moeller
    IZMX
    Circuit Trip
    -
    -
    -
    Schneider Electric
    400 A, 630 A
    ComPacT NSX400...630
    LV4
    ComPact (ComPact NSX400) Circuit Breaker
    Earth Leakage Add-on Protection Module
    220 - 440V ac
    -
    -
    Siemens
    -
    SIRIUS
    -
    Circuit Breaker 3RV1011
    Undervoltage Release
    400V (Volts)
    -
    -
    Schneider Electric
    -
    Acti 9
    iMX
    ARA, ic60 MCB, IDPN Vigi, ild Double Terminal, ilD MCB, iSW-NA, RCA
    Shunt Trip
    100 → 415 V ac, 110 → 130V dc
    Yes
    Green Premium
    Eaton
    -
    Xboard
    -
    N(S)2(-4) Series, N(S)3(-4) Series, NZM2(-4) Series, NZM3(-4) Series
    Shunt Trip
    24V ac/dc
    -
    -
    Schneider Electric
    500A
    Compact
    NSX
    -
    -
    -
    Yes
    Green Premium
    Hager
    160A
    -
    HBA
    MCCBs
    Electronic Earth Leakage
    -
    -
    -
    Siemens
    100mA
    -
    Sentron
    -
    -
    -
    -
    -
    ผลลัพธ์ต่อหน้า