RCCBs | Residual Current Circuit Breakers | RS
การค้าหาล่าสุด / Recently searched

    RCCBs

    An RCCB or residual-current circuit breaker is a safety device used to protect electrical circuits. RCCBs protect people from electric shocks, and electrocution and help prevent electrical fires.

    RS offers an extensive range of high-performance RCCBs and RCDs from leading brands including ABB, Schneider Electric, and Siemens.

    How does an RCCB work?

    An RCCBs incoming current must equal the outgoing current in any circuit. RCCBs can compare the difference in current values between the live and neutral wires. When appliances are working correctly all current entering the appliance through the live wire leaves the appliance via the neutral wire. If a fault occurs some current can flow through the earth wire if there is no earth this can even flow through you. This results in the unequal current flow coming into the device to what is going out, this difference is referred to as residual current.

    What is the difference between an RCCB and an RCD?

    An RCD (residual current device) can keep an electrical system safe by preventing fatal electrical shocks. RCDs can also provide protection from electrical fires. An RCCB is essentially an RCD minus the overload protection. They are typically used in applications where the risk of electric shock is limited. For more detailed information see our in-depth RCDs Guide.

    What are the different types of RCCB and RCD?

    RCCBs and RCDs are usually mounted on DIN rail. They can be 2, 3, or 4 poles. Varying in current ratings, trip sensitivity, and tripping characteristics. All these specifications should be carefully considered depending on your individual needs and application.

    674 สินค้าที่แสดงสำหรับ RCCBs

    Eaton
    RCCB
    40A
    3
    xE?ect
    300mA
    Type S
    xEffect - FBSmV
    240/415V ac
    -
    -
    -
    -
    Eaton
    RCCB
    25A
    2
    xEffect
    500mA
    Type A
    xEffect - FRCmM
    240/415V ac
    -
    -
    -
    -
    Eaton
    RCCB
    63A
    3
    xE?ect
    300mA
    Type S
    xEffect - FBSmV
    240/415V ac
    -
    -
    -
    -
    Eaton
    RCCB
    25A
    2
    xEffect
    100mA
    -
    xEffect - FRCmM
    240 V ACV ac
    -
    -
    -
    -
    Eaton
    RCCB
    25A
    2
    xEffect - Industrial Switchgear
    300mA
    -
    xE?ect - FRCmM-NA
    240/415V ac
    -
    -
    -
    -
    Eaton
    RCCB
    100A
    2
    xEffect
    30mA
    -
    xEffect - FRCmM
    240V ac
    -
    -
    -
    -
    Eaton
    RCCB
    100A
    4
    xEffect
    300mA
    -
    xEffect - FRCmM
    240/415V ac
    -
    -
    -
    -
    Eaton
    RCCB
    40A
    2
    xEffect - Industrial Switchgear
    30mA
    -
    xE?ect - FRCmM-NA
    240/415V ac
    -
    -
    -
    -
    Eaton
    RCCB
    63A
    4
    xEffect - Industrial Switchgear
    30mA
    Type A
    xE?ect - FRCmM-NA
    240/415V ac
    -
    -
    -
    -
    Eaton
    RCCB
    80A
    4
    xE?ect
    -
    Type A
    xE?ect - FBHmV
    240/415V ac
    -
    -
    -
    -
    Schneider Electric
    RCBO
    32A
    4
    Acti9
    300mA
    Type C
    iC60
    380 → 415V ac
    -
    -
    -
    -
    Schneider Electric
    RCBO
    10A
    4
    Act 9
    30mA
    Type C
    iC60
    380 → 415V ac
    -
    -
    -
    -
    Schneider Electric
    RCCB
    63A
    2
    Acti9
    300mA
    Type AC
    A9R1
    240V ac
    -
    -
    -
    -
    Schneider Electric
    RCBO
    60A
    1
    Resi9
    500mA
    Type A
    R9F
    250V ac
    -
    -
    -
    -
    Siemens
    RCCB
    25A
    2
    SENTRON
    30mA
    Type AC
    5SV43
    230V
    -
    -
    -
    -
    ABB
    Self Resetting Short Circuit Limiter
    63A
    2
    -
    -
    -
    S802S
    690V
    -
    -
    -
    -
    Eaton
    RCCB
    63A
    2
    xEffect
    30mA
    Type A
    xEffect - FRCmM
    110V
    -
    -
    -
    -
    Schneider Electric
    RCCB
    100A
    2
    Acti9
    -
    -
    A9R
    240V
    -
    -
    -
    -
    Legrand
    -
    63A
    2
    DX3
    30mA
    -
    -
    230V
    -
    -
    -
    -
    Eaton
    RCCB
    25A
    4
    Moeller
    -
    -
    187456 PFIM
    230V ac
    -
    -
    -
    -
    ผลลัพธ์ต่อหน้า