Wireless 10 year battery smoke alarm

  • RS Stock No. 123-5778
  • หมายเลขชิ้นส่วนของผู้ผลิต / Mfr. Part No. FHB10W
  • ผู้ผลิต / Manufacturer FireHawk Safety Products
ข้อมูลทางเทคนิค / Technical Data Sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): CN
รายละเอียดสินค้า / Product Details

Firehawk FHB10W Series Wireless Battery Operated Smoke Alarm

Firehawk FHB10W series battery operated Optical smoke alarms have a 10-year life complete with TSE Thermal Stability Enhancement including Wireless Interlink. The high performing wireless interlink alarm is used and recommended by the UK Fire and Rescue Services. The alarm is specially designed for easy installation and have the same quality as FHB10 smoke alarms. In addition, the alarm features a silence button, audible low battery warning plus, an end of alarm life indicator. The FHB10W series is compatible for use with the FH700HIA sensory alarm system.

FEATURES and BENEFITS:
10-year Optical smoke alarm
TSE – Thermal Stability Enhancement
Intelligent Wireless interlink technology – battery operated
High performing
Smoke detection
Silence buttons
Audible low battery warning
Alarm life indicator
Compatible with Firehawk FH700HIA sensory Alarm
Recommended by the UK Fire and Rescue Services
10-year warranty

Note

RECOMMENDED AND USED BY THE UK FIRE AND RESCUE SERVICES

Standards

EN 15604:2005

Stand Alone Fire Alarms

Battery Operated

A comprehensive range of battery operated smoke alarms all carrying the BS Kitemark and compliance with BS5446:Pt1:1990. They are suitable for BS5839:Pt6:1995 Fire Systems grade F.

Mains Powered Interconnectable

All new properties are required by the Building Regulations to have installed mains powered smoke alarms. Refurbished properties and small commercial premises may also be required to install mains operated alarms.
BS5839:Pt.6:1995 acknowledges that all three types of detection i.e. ionisation, optical and heat detection, need to be considered depending on the installation circumstances. It is also recommended that some form of back-up is used in the event of mains failure.
Optical alarms are recommended for use in circulation spaces such as landings and hallways. Ionisation alarms are more appropriate for use in living rooms and fixed temperature heat alarms are designed for use in kitchens and garages. All alarms must be interconnected using 3 core and earth cable.

At least one alarm on each floor of the house
Max. 7.5m between alarms and no more than 3m from bedroom doors
Alarms can be wired off lighting circuits if the alarm has its own backup supply
Locate as close as possible to centre of ceiling, away from light fitting
Alarms must be kept clean at all times and particularly whilst building work or decoration is in progress

Mains Operated

Suitable for new buildings to allow conformity to building regulations. Each unit features an 85dB at 3m internal alarm and interconection facility which allow the sensing unit to trigger up to 11 other detectors, for added safety and particularly when one unit might not be heard in a large building or from behind closed doors.
The unit causing the alarm also has an indicator to show the source. Each unit has a green continuous LED to indicate mains present.
These products can also be fitted using the surface mounting kits. A relay output option is also available to allow for triggering of remote indicators or other communication/alarm systems. All units are supplied complete with instructions.
290-3816 = 12V Operating Voltage with Relay Output.

คุณสมบัติ / Specifications
คุณสมบัติ Value
Power Indicator Yes
45 มีของพร้อมจัดส่งภายใน (In stock for delivery within) 5 - 8 วันทำการ (working days)
ราคา / Price Each
THB 1,751.74
(exc. VAT)
THB 1,874.36
(inc. VAT)
Units
Per unit
1 +
THB1,751.74
Related Products
Exitguard 24 hour door alarm. Ideal for protecting ...
Description:
Exitguard 24 hour door alarm. Ideal for protecting fire exit doors in supermarkets, hotels, warehouses, leisure centres and all types of public buildings. An integral high power sounder is activated when the door is opened. High output sounderNine digit keypad ...
The Terxon SX alarm panel is an entry ...
Description:
The Terxon SX alarm panel is an entry level alarm center for smaller properties. 9 zones ensure gap-free security. The system has 8 freely programmable zones for wired detectors. Zone 9 is the sabotage zone. Only NC detectors can be ...
The Keyguard range includes snap-off plastic windows to ...
Description:
The Keyguard range includes snap-off plastic windows to release keys with or without battery powered inbuilt alarm. Other Keyguard options include volt-free contacts for specialist applications. Key cases are made of plastic without glassSnatch off plastic windowCan be wired into ...
A wall mounted CALL button in white ABS ...
Description:
A wall mounted CALL button in white ABS complete with a single gang mounting box. This is a non-latching unit with a N/O contacts. The buzzer has separate terminals for acknowledge purposes. The LED current limit resistor is provided for ...