PR Electronics 3100 Series Isolating Signal Converter, Current, Voltage Input, Current, Voltage Output, 16.8 →
- RS Stock No.:
- 796-7070
- หมายเลขชิ้นส่วนของผู้ผลิต / Mfr. Part No.:
- 3104
- ผู้ผลิต / Manufacturer:
- PR Electronics
- RS Stock No.:
- 796-7070
- หมายเลขชิ้นส่วนของผู้ผลิต / Mfr. Part No.:
- 3104
- ผู้ผลิต / Manufacturer:
- PR Electronics
ข้อมูลทางเทคนิค / Technical Data Sheets
Legislation and Compliance
- COO (Country of Origin):
- DK
รายละเอียดสินค้า / Product Details
3100 Type - Isolated Converter
3104, 3109 and 3114 type are for isolation and conversion of standard DC signals.
Suitable for galvanic separation of analog DC signals and elimination of ground loops and measurement of floating signals.
Suitable for galvanic separation of analog DC signals and elimination of ground loops and measurement of floating signals.
Features and Benefits
Conversion of standard DC signals
Slimline housing of 6 mm
Power supply and signal isolator for 2-wire transmitter
Loop supply >17 V
DIP-switch configured
Inputs and outputs are floating and galvanically separated
Isolation 2.5 mm²
Installation in ATEX Ex zone 2 / IECEx zone 2 / FM division 2
Slimline housing of 6 mm
Power supply and signal isolator for 2-wire transmitter
Loop supply >17 V
DIP-switch configured
Inputs and outputs are floating and galvanically separated
Isolation 2.5 mm²
Installation in ATEX Ex zone 2 / IECEx zone 2 / FM division 2
DIP-switch programming
Re-calibration is not needed after changing the DIP-switch range settings. Just change the DIP-switch, cycle the power to the unit and obtain the new, pre-calibrated I/O range. HART programming is enabled for selected devices.
Mounting
Devices can be mounted both vertically and horizontally with no air gap separation required. The devices snap onto a power rail or DIN rail and are easily detached by lifting the bottom lock.
High level of isolation
Safe galvanic isolation of 2.5 kVAC provides high noise immunity and prevents ground loops for accurate delivery of the process signal to your control system.
Device status indicators
A front LED indicates device status, e.g. an error in the set-up, sensor or hardware.
Over voltage- / polarity protection
All terminals can withstand up to ±31.2 VDC and are protected against incorrect supply wiring to ensure safe, error-free installation.
PR Electronics DIN Rail Mounting
คุณสมบัติ / Specifications
คุณสมบัติ | Value |
---|---|
Module Type | Signal Isolator |
Input Signal Type | Current, Voltage |
Output Signal Type | Current, Voltage |
Input Range | 0 → 10.25 V, 0 → 20.5mA |
Output Range | 0 → 10 V dc, 0 → 20.5mA |
Supply Voltage | 16.8 → 31.2V dc |
Hazardous Area Certification | ATEX |
Mounting Type | DIN Rail Mount |
Operating Temperature Range | -25 → +70°C |
Series | 3100 |
Minimum Operating Temperature | -25°C |
Maximum Operating Temperature | +70°C |