AD585AQ, Sample & Hold Circuit, 3μs Dual Power Supply, 14-Pin CERDIP

  • RS Stock No. 759-0856
  • หมายเลขชิ้นส่วนของผู้ผลิต / Mfr. Part No. AD585AQ
  • ผู้ผลิต / Manufacturer Analog Devices
ข้อมูลทางเทคนิค / Technical Data Sheets
Legislation and Compliance
RoHS Certificate of Compliance
รายละเอียดสินค้า / Product Details

Sample and Hold, Analog Devices

This Quad Sample-and-Hold amplifier comprises of four internal buffer amplifiers and hold capacitors, and is suitable for a broad range of Sample-and-Hold applications. Economically designed, this device is typically used in signal processing systems, medical instrumentation and test equipment.

Sample and Hold Circuits

คุณสมบัติ / Specifications
คุณสมบัติ Value
Acquisition Time 3µs
Number of Sample and Holds 1
Power Supply Type Dual
Typical Dual Supply Voltage -10.8 V, 5 V
Mounting Type Through Hole
Package Type CERDIP
Pin Count 14
Dimensions 19.94 x 7.87 x 3.56mm
Length 19.94mm
Width 7.87mm
Height 3.56mm
Maximum Operating Temperature +85 °C
Minimum Operating Temperature -25 °C
สินค้าหมดชั่วคราว, จะเป็นแบ๊คออเดอร์จัดส่งเมื่อในสต๊อกมีของพร้อมส่ง
ราคา / Price Each
THB 1,507.94
(exc. VAT)
THB 1,613.50
(inc. VAT)
Units
Per unit
1 - 9
THB1,507.94
10 - 49
THB1,449.94
50 - 99
THB1,398.15
100 - 249
THB1,351.56
250 +
THB1,324.53
ตัวเลือกบรรจุภัณฑ์ / Packaging Options :
Related Products
The Offline, AC-DC switching regulators, feature control in ...
Description:
The Offline, AC-DC switching regulators, feature control in current and voltage mode. The NCP105x series are gated oscillator power switching regulators. Applications include robust and highly efficient power supplies, essentially Switch Mode Power Supply (SMPS).
The AD823x devices are integrated signal conditioning blocks ...
Description:
The AD823x devices are integrated signal conditioning blocks for ECG and other biopotential measurement applications. They are designed to extract, amplify and filter small biopotential signals in the presence of noisy conditions, such as those created by motion or remote ...
Heart-Rate Monitoring (HRM) and saturation of peripheral capillary ...
Description:
Heart-Rate Monitoring (HRM) and saturation of peripheral capillary Oxygen (SpO2)Simultaneous Support of 3 LEDs24-Bit Representation of the Current Input from a PhotodiodePulse Frequency 10 SPS to 1000 SPSI²C-Bus interface.
Analogue to Digital Converters translate analogue electrical signals ...
Description:
Analogue to Digital Converters translate analogue electrical signals for data processing purposes. Analog Devices offers the industry’s largest range of A/D converter products that design engineers depend on for reliable performance in the harshest environments, both on Earth and in ...