Schneider Electric Configurable 24 V ac/dc Safety Relay Single or Dual Channel With 3 Safety Contacts

  • RS Stock No. 360-4346
  • หมายเลขชิ้นส่วนของผู้ผลิต / Mfr. Part No. XPSAF5130
  • ผู้ผลิต / Manufacturer Schneider Electric
ข้อมูลทางเทคนิค / Technical Data Sheets
Legislation and Compliance
สถานะRoHS: ไม่สามารถใช้ได้
COO (Country of Origin): ID
รายละเอียดสินค้า / Product Details

Schneider Electric | Preventa XPSAF Series | Safety Relays

Simple and effective safety monitoring has never been more crucial in today's highly automated world. Prevention is key to site safety, that's why Schneider Electric offers a Safety Relay in the form of the 'Preventa XPSAF' module that is second to none. Being able to monitor faults with devices along a circuit has the power to stop emergency situations from even occurring.

Features and benefits:

• Single-channel with 3 N/O safety outputs

• Monitoring of a movable guard, with emergency stop monitoring 1 or 2 channel wiring usable.

• Configurable type of start is readily available for the type of activation you wish for your circuit.

• Monitoring of single safety functions, providing an automated solution for use with applications such as emergency push stop buttons or switches.

• Unlimited synchronisation between time inputs.

• Slin in design, with just 22.5mm of width meaning it can fit nicely even in space constraint spaces.

• Accepts cable up to 2.5mm²

• Symmetrical DIN rail support, offering flexible and versatile safety system installation.

• Local signalling in the form of LEDs.

Protection ratings & Safety features (see datasheet for specifics) -

• Impressive line resistance is available, varying between 90 to 100 Ohm (Ω).

• Input protection type is internal, electronic.

• EN1088/ISO 14119, EN 60204-1, EN/IEC 60947-5-1, EN/ISO 13850

• CSA, TUV & UL listed

• IP 40 (enclosure) for protection against small objects up to 1mm such as tools, wires and small wires.

• IP 20 (terminals) for protection against solid objects such as fingers, smaller tools up to 12mm.

• -25 to 60°C temperature range for operation, suitable in varying levels of heat/freezing temperatures.

Applications -

All dangerous machinery requires an automated solution to prevent harm to immediate users and also prevent damage to the machinery. Below are some of the safety applications

• Coded Magnetic Switch (CMS) to prevent tampering by unauthorised users.


• Time delay input if needed allowing you to set up your own time function.

• Light curtains / Two-hand control safety circuits

• Sensing mats and edges

Standards

IEC 204-1; EN 292; EN 418; EN 60204-1; EN 1088

Approvals

BG, UL, CSA

คุณสมบัติ / Specifications
คุณสมบัติ Value
Supply Voltage 24 V ac/dc
Number of Channels 1, 2
Function Safety Switch/Interlock
Safety Contacts 3
Range Preventa
Terminal Type Screw
Length 99mm
Depth 114mm
Width 22.5mm
163 มีของพร้อมจัดส่งภายใน (In stock for delivery within) 5 - 8 วันทำการ (working days)
ราคา / Price Each
THB 9,830.98
(exc. VAT)
THB 10,519.15
(inc. VAT)
Units
Per unit
1 - 5
THB9,830.98
6 +
THB9,731.63
Related Products
The G9SA family offers a line-up of compact ...
Description:
The G9SA family offers a line-up of compact and expandable safety relay units. Modules with safe OFF-delay timing are available as well as a two hand controller. Simple multiplication of safety contacts is possible by using the connection on the ...
The Phoenix Contact 2700525 safety relay is designed ...
Description:
The Phoenix Contact 2700525 safety relay is designed for emergency stop (E-Stop), light grids and safety doors up to Cat.4/PL e according to ISO 13849-1, SILCL 3 according to IEC 62061With 3 enabling current path and 1 signalling current path ...
The BG5924 is a highly compact safety switch ...
Description:
The BG5924 is a highly compact safety switch device for the construction of emergency stop switches. It serves to protect personnel and machines in accordance with the EC directive for machines 89/392/EEC, IEC 204-1, EN 60204-1, DIN VDE 0113-1. Single-channel ...
Safety category 4 in accordance with DIN EN ...
Description:
Safety category 4 in accordance with DIN EN 954Output: 2 N/Os, 1 N/C1 or 2-channel configurationLine termination detection on the ON buttonProgrammable: Activation via the ON button or automatic ON function when the operating voltage is appliedProgrammable: With / without ...