Preventa XPSMCM Output Module, 2 Inputs, 4 Outputs, 24 V dc

  • RS Stock No. 111-3518
  • หมายเลขชิ้นส่วนของผู้ผลิต / Mfr. Part No. XPSMCMER0004
  • ผู้ผลิต / Manufacturer Schneider Electric
ข้อมูลทางเทคนิค / Technical Data Sheets
Legislation and Compliance
สถานะRoHS: ไม่สามารถใช้ได้
COO (Country of Origin): IT
รายละเอียดสินค้า / Product Details

Preventa Safe Relay Output Modules, XPSMCM

The Preventa XPSMCM safe relay output modules have a compact designed, 22.5 x 99 x 114.5 mm, the same size as a typical safety relay.

Features and Benefits

Removable screw-type terminal blocks for connecting the machine bus or networks channels and/or the power supply
Symmetrical DIN Rail locking clip
Green premium product
RoHS compliant

Stock no. 111-3517

2 forcibly guided contact safety relay output (2 NO + 1 NC) modules without backplane connection not connected to the backplane bus
1 input for Start/Restart interlock and external device monitoring (EDM)
Does not require the expansion bus connector as it is directly wired to the selected OSSDs

Stock no. 111-3518

4 forcibly guided contact safety relay output (2 NO + 1 NC) modules without backplane connection not connected to the backplane bus
2 inputs for Start/Restart interlock and external device monitoring (EDM)
Does not require the expansion bus connector as it is directly wired to the selected OSSDs

Stock no. 111-3521

4 forcibly guided contact safety relay output modules with backplane connection
Expansion module with 4 independent safety relay outputs and the corresponding 4 inputs for the external feedback contacts (EDM)
The relay can be configured according to Category 1, 2 and 4 architectures
Connected to the safety controller CPU via the expansion bus connector

Stock no. 111-3522

4 forcibly guided contact safety relay output modules with backplane connection
Expansion module with 4 independent safety relay outputs and the corresponding 4 inputs for the external feedback contacts (EDM)
The relay can be configured according to Category 1, 2 and 4 architectures
8 configurable status outputs
Connected to the safety controller CPU via the expansion bus connector

Note

The XPSMCM system is TUV SUD certified to Cat 4, PLe EN/ISO 13849-1 and SILCL 3 IEC/EN 61508 & IEC/EN 60261 standards.

Approvals

CE, cULus, TUV.

คุณสมบัติ / Specifications
คุณสมบัติ Value
Range Preventa
Series XPSMCM
Type Output Module
For Use With Preventa Modular Safety Controller
Supply Voltage 24 V dc
Normal State Configuration 2NC, 4NO
Number of Inputs 2
Number of Outputs 4
Power Rating 3 W
Mounting Style DIN Rail Mount
Dimensions 22.5 x 99 x 114.5 mm
Terminal Type Screw
สินค้าหมดชั่วคราว (Temporarily out of stock) - จะเป็นแบ๊คออเดอร์จัดส่ง (back order for despatch) 06/03/2020, จัดส่งภายใน (delivery within) 5 - 8 วันทำการ (working days)
ราคา / Price Each
THB 8,565.56
(exc. VAT)
THB 9,165.15
(inc. VAT)
Units
Per unit
1 +
THB8,565.56
Related Products
Professional range of IDEM VIPER Safety Relays with ...
Description:
Professional range of IDEM VIPER Safety Relays with pluggable and screw terminals. The safety relays incorporate expansion units. The relays can be directly wired to increase the number of safety output contacts. Designed to meet the latest safety standard and ...
The PSR safety relay extension units are for ...
Description:
The PSR safety relay extension units are for contact expansion. Single and two-channel control (stock no. 768-5147 & 801-5937), with one-channel connection only (stock no. 666-7113 & 801-5934)5 enabling current paths, 1 signalling current path, and 1 confirmation current pathInput ...
The 3TK28 56 and 3TK28 57 safety expansion ...
Description:
The 3TK28 56 and 3TK28 57 safety expansion modules are used to increase the number of enabling circuits of the SIRIUS 3TK28 Safety Relay/Contactor. The expansion module will retain the same safety integrity as the base unit. Available with spring-loaded ...
The ESR5 safety relay from Eaton is designed ...
Description:
The ESR5 safety relay from Eaton is designed to monitor the signals from safety devices at all times and switch off quickly and reliably in an emergency. Suitable for applications that meet the highest safety requirements in accordance with EN ...