10 A, RCD Switch, Trip Sensitivity 300mA, DIN Rail, DIN Rail Mount Acti 9 iDPN

  • RS Stock No. 790-9428
  • หมายเลขชิ้นส่วนของผู้ผลิต / Mfr. Part No. A9D48610
  • ผู้ผลิต / Manufacturer Schneider Electric
ข้อมูลทางเทคนิค / Technical Data Sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): ES
รายละเอียดสินค้า / Product Details

Acti9 Vigi iDPN H RCBOs

iDPN Vigi is a range of residual current devices that integrates MCB and RCD functions and provides protection against overcurrents and insulation faults

VisiSafe green strip indicates the safe position of contacts for complete operator safety
Double visiTrip red indicator allows easy detection if the fault comes from short circuit, overload or due to an isolation fault
3 different ranges available: 4.5kA (iDPNa Vigi), 6kA (iDPN N Vigi) and 10 kA (iDPN H Vigi)

คุณสมบัติ / Specifications
คุณสมบัติ Value
Current Rating 10 A
Trip Sensitivity 300mA
Rated AC Voltage 230 V
Mounting Style DIN Rail, DIN Rail Mount
Range Acti 9
Series iDPN
สินค้าหมดชั่วคราว (Temporarily out of stock) - จะเป็นแบ๊คออเดอร์จัดส่ง (back order for despatch) 31/03/2020, จัดส่งภายใน (delivery within) 5 - 8 วันทำการ (working days)
ราคา / Price Each
THB 8,174.24
(exc. VAT)
THB 8,746.44
(inc. VAT)
Units
Per unit
1 +
THB8,174.24
Related Products
One block can be fitted to each side ...
Description:
One block can be fitted to each side of the deviceFor signalling the ’ON’ or ’OFF’ switch positionsWith 1 NO + 1NC contactsRated voltage 240Vac.
Residual Current operated circuit breaker for Personnel and ...
Description:
Residual Current operated circuit breaker for Personnel and fire protectionFree from FCKW and silicone2 or 4 poleInstant tripping, surge current withstand capability >1kAMains connection alternatively from above or underneathReciprocally sleeve terminals with wire protection Lower combination clamp for the ...
Professional range of Schneider Electric auxiliary switches. All ...
Description:
Professional range of Schneider Electric auxiliary switches. All the auxiliaries can be DIN Rail mounted. Typical applications include bank cash machines, cold storage rooms, lifts and public lighting. Single, Double or 4 Pole versionsDIN Rail mountInstantaneous break time.
AC rated voltage version 115/230VAC onlyDetects earth fault ...
Description:
AC rated voltage version 115/230VAC onlyDetects earth fault currents using separate toroidSelectable sensitivity and time delay with tamperproof coverMust be used with a suitable BZCT type toroidType A tripping characteristicsTest and Reset buttons2 relay outputsLED indication status for supply, leakage ...