Eaton 690 V ac Motor Protection Circuit Breaker, 3P Channels, 16 → 20 A, 50 kA

  • RS Stock No. 312-5310
  • หมายเลขชิ้นส่วนของผู้ผลิต / Mfr. Part No. 088918 | PKZM0-20-T
  • ผู้ผลิต / Manufacturer Eaton
ข้อมูลทางเทคนิค / Technical Data Sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
รายละเอียดสินค้า / Product Details

Transformer Protection Switches, PKZM0-T

DIN rail mounted, mechanically reset protection devices.
Transformer short circuit and overload protection
The short circuit release is set to 20 x Iu, so even transformers that have high inrush currents have protection
Rotary handle for ease of trip indication after a fault has occurred
Rated operational voltage 690V
Trip-fault indication
Phase failure sensitive
93 x 45 x 76mm (H x W x D)

Note

PKZMO accessories can be used allowing additional functions.

คุณสมบัติ / Specifications
คุณสมบัติ Value
Current Range 16 → 20 A
Number of Poles 3P
Breaking Capacity 50 kA
Terminal Type Screw
Voltage Rating 690 V ac
Length 93mm
Width 45mm
Depth 76mm
Dimensions 93 x 45 x 76 mm
Series PKZM 0
5 มีของพร้อมจัดส่งภายใน (In stock for delivery within) 4-6 วันทำการ (working days)
ราคา / Price Each
THB 3,844.59
(exc. VAT)
THB 4,113.71
(inc. VAT)
Units
Per unit
1 +
THB3,844.59
Related Products
Covers motors up to 16A (7.5kW)Local isolatorProtects against ...
Description:
Covers motors up to 16A (7.5kW)Local isolatorProtects against overloads, short circuits, phase failure and faults in cabling or wiringThese Motor Starters can be used in conjunction with ABB Contactors, stock no. 445-0897 typicallyAccessories available from auxiliary/signal contacts to under voltage ...
The ABB MS132 series of manual motor starters ...
Description:
The ABB MS132 series of manual motor starters are compact highly reliable devices used to manually switch on and off motors. The MS132 series protects the motors reliably, without the need for a fuse, from short-circuits, overload and phase failures. ...
Maximum rated current 100A (45kW @ 400V a.c.)Rated ...
Description:
Maximum rated current 100A (45kW @ 400V a.c.)Rated operational voltage: 690VShort-circuit proof to 50kA @ 400V a.c.Maximum switching frequency; 15 operations/hourMechanical life; 105 operationsAmbient temperature range; –20 to +60 ° CLong term stabilityManual resetLockable in off position.
Protecting your motors from faults such as an ...
Description:
Protecting your motors from faults such as an overload of high voltage, short circuits, or relay shutdowns is vital in an age where any downtime can be detrimental to a business and its operations. Schneider Electric has built a reliable, ...