Schneider Electric Thermal Overload Relay NO/NC, 12 → 18 A, 18 A

  • RS Stock No. 727-6204
  • หมายเลขชิ้นส่วนของผู้ผลิต / Mfr. Part No. LRD318
  • ผู้ผลิต / Manufacturer Schneider Electric
ข้อมูลทางเทคนิค / Technical Data Sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): FR
รายละเอียดสินค้า / Product Details

Three-pole Thermal Overload Relays

Three-pole thermal overload relays designed to protect ac circuits against overloads, phase failure, long starting times and prolonged stalling of the motor.

Adjustable relay setting dialTest buttonStop buttonManual/auto resetTrip indicatorSealable cover1N/O & 1N/C auxiliary contactsDirect mounting beneath three-pole contactors or independent mounting on DIN railInsulation voltage 600V, Withstand Voltage 6kV

Approvals

UL and CSA

คุณสมบัติ / Specifications
คุณสมบัติ Value
FLC Motor Rating 12 → 18 A
Contact Current Rating 18 A
Range TeSys D
Contact Voltage Rating 1 kV ac
Mounting Style DIN Rail Mount, Plate
Series LRD3
Normal State Configuration NO/NC
Number Of Auxiliary Contacts 2
Terminal Type Screw
Width 55mm
Depth 116mm
Length 70mm
Minimum Operating Temperature -20°C
Operating Temperature Range -20 → +60 °C
Maximum Operating Temperature +60°C
7 มีของพร้อมจัดส่งภายใน (In stock for delivery within) 4-6 วันทำการ (working days)
ราคา / Price Each
THB 3,570.82
(exc. VAT)
THB 3,820.78
(inc. VAT)
Units
Per unit
1 +
THB3,570.82
Related Products
Designed to create extremely compact motor starters, the ...
Description:
Designed to create extremely compact motor starters, the LR9 series can be mounted below the LC1-D115/150 and LC1-E contactors (1, 3 or 4 pole F range contactors), Featuring built in alarm function this range of overload relays have a high ...
Manual or automatic re-settings availableDirect mounting on BF09 ...
Description:
Manual or automatic re-settings availableDirect mounting on BF09 - BF38 contactorsRated insulation voltage Ui: 690VFrequency limit 0-400HzOperating temperature -25 to +60°CCan be mounted on contactor or seperatelyTest button - trip indicator.
Electronic overload relays are the alternative to the ...
Description:
Electronic overload relays are the alternative to the thermal overload relays; they offer reliable and fast protection for motors in the event of overload or phase failure. Overload protection – trip class 10E, 20E, 30E selectablePhase loss sensitivityAdjustable current setting ...
TF range up to 38 AmpsOverload protection class ...
Description:
TF range up to 38 AmpsOverload protection class 10 but does have a adjustable setting Phase loss sensitivityAutomatic or manual reset selectableSTOP and Test function Temperature consumption -25 → +60 °C.